Products Micro module data center11 Single cabinet/single row micro module33
Single cabinet/single row micro module Data Center

Basic Features

Efficient and energy-saving

The front and rear cold channels of the cabinet are closed to improve the cooling efficiency of the air conditioning.

●Variable frequency compressor, matched with load size, reduces overall energy consumption.

 

Stable and reliable

● Support N+1/2N design to ensure stable operation of IT equipment.

●Emergency fans serve as emergency cooling.

●Stable operation of ultra wide voltage input, with phase sequence detection and other electrical guarantees.


Source protection function.                                                      

● Intelligent call self start function. Flexible and diverse

● Low temperature components or long connected pipe components can be selected to ensure reliable operation of the unit in more severe on-site conditions.

 

Fast delivery speed

●Factory prefabricated, quick on-site splicing, plug and play.

●Standard modular construction, easy deployment, and quick deployment,

The later expansion will not affect each other, and the delivery target speed will increase by 50%.

 

Intelligent control

●Local display on a 10 inch large touch screen, not occupying the U position.

●Can manage intelligent devices such as UPS, air conditioning, power distribution, and temperature and humidity

Non intelligent devices such as temperature sensors, smoke detectors, and access control.

●Through the WEB interface, remote comprehensive monitoring of unmanned computer rooms can be achieved, ensuring stable and reliable remote monitoring of the computer room to achieve unmanned or few people on duty, providing strong guarantees for efficient management and safe operation of the computer room.

 

Flexible and diverse

●The cabinet is the computer room and can be flexibly placed.

●The standard configuration is a dual closed cold and hot channel, or a single closed cold channel.

 

Single row micro module classification

● Single cabinet

● Single row multi cabinet

 

Naming rules

1683767589360832.png

Single row micro module standard configuration

 

System

Model

Control   Cabinet

IT cabinet

Battery   Cabinet

Battery   position

Battery   capacity

UPS Power

Cooling Power

Total cabinet   positions

Single cabinet

Lx-MD31R103J103U-12

1

0

0

Internal

12V9Ah×6

3kVA×1

3.5kW×1/ Rack

1

1+1

Lx-MD32R105J106U-12

1

1

0

Internal

12V9Ah×16

6kVA×1

5kW×1/ Rack

2

1+2

Lx-MD33R107J110U-12

1

2

0

Internal

12V9Ah×16

10kVAx1

7.5kW×1/ Rack

3

1+3

Lx-MD34R112J120U-12

1

3

0

Internal

12V40Ah×16

20kVA×1

12.5kW×1/ Rack

4

1+4

Lx-MD35R112L120U-12

1

4

0

Internal

12V65Ah×16

20kVAx1

12.5kW×1/ Inter column

6

1+4

Lx-MD35R112L120U-12C

1

4

1

External

12V10OAh×16

20kVA×1

12.5kW×1/ Inter column

7

1+5

Lx-MD36R115L120U-12

1

5

1

Internal

12V100Ah×16

20kVAx1

15kW×1/ Inter column

8

1+5

Lx-MD36R115L120U-12C

1

5

0

External

12V100Ah×16

20kVA×1

15kW×1/ Inter column

7

1+6

Lx-MD37R212L130U-12

1

6

2

Internal

12V100Ah×32

30kVA×1

12.5kW×2/ Inter column

11

1+6

Lx-MD37R212L130U-12C

1

6

0

External

12V10OAh×32

30kVA×1

12.5kW×2/ Inter column

9

1+7

Lx-MD38R212L130U-12

1

1

2

Internal

12V10OAh×32

30kVA×1

12.5kW×2/ Inter column

12

1+7

Lx-MD38R212L130U-12C

1

7

0

External

12V100Ah×32

30kVA×1

12.5kW×2/ Inter column

10

Single cabinet structure diagram

1684391972144485.jpg

Single row multi cabinet structure diagram

1683767365190285.png


Technical Specifications

Item

Description

System


Single cabinet

1+1

1+2

1+3

1+4

1+5

1+6

1+7


Overall parameters

Power supply system

220V,50Hz,1Ph+N+PE

380V,50Hz,3Ph+N+PE


Working Temperature

0~40℃


Humidity range

5~95%


Altitude

0~4000m(Reduce   capacity for use   above 1000m)


Cabinet System

Cabinet dimension:W×D×H(mm)

600×1200×2000


Cabinet composition

Control   cabinet+IT cabinet+air   conditioning cabinet+battery cabinet (optional)


Cold and hot channels

Cold   and hot channels, double   closed, cold channels, single closed


Device available space

Free space

42U×(N-1), the specific available space depends on the configuration.


Distribution system

System input

Input main switch

40A/2P

63A/2P

100A/2P

80A/3P

125A/3P


System output

Output circuit

Configure according to user requirements


UPS

Capacity

3kVA

6kVA

10kVA

20kVA

30kVA


Configuration

Single UPS

Single/DualUPS


Power Factor

0.8

0.9


Efficiency

93% above


PDU

Installation method

Vertical installation


Type

National standard


Configuration

32A,GB16×10A+4×16A


Battery Pack

Capacity

9Ah


QTY

0~4


Backup

Backup mode

Battery pack/rack/cabinet


Battery cabinet

Backup time

15 minutes to 4 hours, configured according   to user requirements


Dynamic loop system

Integrated monitoring machine

10寸 touch screen


SMS alarm

Optional


Atmosphere light

standard configuration


Audible and Visual Alarm

standard configuration


Water immersion

standard configuration


Temperature sensor

standard configuration


Door contact

standard configuration


Smoke Detector

standard configuration


infrared

Optional


Cooling 

system

Cooling

Refrigeration capacity

3.5kW×1

5kWx1

7.5kW×1

12.5kW×1

12.5kW×1

15kw×1

12.5kW×2

12.5kW×2


Classification

Rack mounted variable frequency

Inter column frequency conversion



Work Voltage

220V

380V


Eemergency ventilation

Exhaust air volume(myh)

720

1440

2160

2880

3600

4320

5040

5760


Work Voltage

220v


Dimension/GW

Package dimension: 

W×D×H(mm)

734×1360×2200(unit)


NW

140kg(Control Cabinet),100kg(IT Cabinet)