PDM series integrated UPS 20 ~ 150kVA

Product profile

PDM series-bulk UPS power supply adopts fully modular design to support smooth expansion of 20-150 KVA capacity. It combines the UPS and power distribution systems. Can be directly load, flexible optional. It can fully eliminate the impact of various power grid problems on key loads, has the characteristics of reliable, efficient, intelligent and flexible, simple maintenance, and can provide ideal power supply protection for customers in medium-sized power supply scenarios.


Basic Features

Application area

Small and medium-sized data center, IT computer room, financial institutions, traffic dispatch center, security monitoring, etc.


Functional characteristics

1.UPS and power distribution of multiple cabinets in one, save space.

2.138V-485V ultra-wide input voltage range, to adapt to the harsh power grid.

3.Full modular design of power module, bypass module and control module.

4.Each module supports hot plug, capacity expansion on demand, and is easy to maintain.

5.7-inch color touch screen. Circle shape display, easy to operate.

6.The main input mode is optional, and the number of battery qty 30-50pcs is flexible and adjustable.

Technical Specifications


Cabinet capacity

150kVA

Module capacity

20kVA,25kVA,30kVA

Module number

Maximum 5+1

input

Input system

3-phase+N line+ground wire

Input voltage

380/400/415VAC

Input frequency

50/60Hz

Input power factor

>0.99

Current-current harmonic distortion   degree

THD<3% (100% linear load)

Voltage range

138~485VAC

Frequency range

40-70Hz

Bypass

Bypass voltage

380/400/415VAC

Voltage range

Adjustable; 

220V upper limit: 220V+25% (optional +10%, +15%, +20%) 230V+20% (optional +10%, +15%)
  240V+15% (optional +10%) 

Lower limit: -45% (optional-10%, -20%, -30%)

Bypass frequency range

50/60Hz (lock) ±1Hz, ±3Hz, ±5Hz

Voltage

Voltage range

±180~±300Vdc (30-50 knots even number adjustable, default 40 knots)

Output

Output power factor

1

Rated output voltage

380/400/415VAC

Rated output frequency

50/60Hz

Outputvoltage harmonic distortion

<2% (linear load), <5% (nonlinear load)

Inverter overload

110%, after 1 hour; 125%, 10 minutes; 150%,1 minute;

>150%, 200ms

System

Efficiency

95.50%

Levels of protection

IP 20

Communication interface

RS485, dry contact SNMP card, EPO

Running temperature

0-40c

Storage temperature

-25℃~70℃

Relative humidity

0-95% (no condensation)

Distributing

Input mode

Single MCCB / dual ATS input (optional)

Input specification

400A

UPS distributing

250A*3, MCCB

IT distributing

32A/1P*48, MCB

Power distribution

63A/3P*8,16A/1P*3, MCB

Size

Depth×width×high (mm)

1100×600×2000 or 1200×600×2000

* The above parameters may be adjusted and changed, please refer to the physical object.